Sign In | Join Free | My wneducation.com |
|
Brand Name : Neware
Model Number : CT-4008T-5V50mA-164
Certification : CE
Place of Origin : China
MOQ : 1 Unit
Price : USD negotiation per Unit
Payment Terms : T/T
Supply Ability : 100 Units Per Month
Delivery Time : 8 working days
Packaging Details : Carton box , 530 - 360 - 130mm
Voltage To : -5V - 5V
Charge discharge Current : Range1 , 5uA – 1mA Range2 , 1mA – 25mA Range3 , 25mA – 50mA
Precision : 0.05 percent of FS
Stability : 0.05 percent of FS
Size : 480 - 330 - 70 mm
Software Protection : Upper Voltage limit
Neware Battery Cell Test Equipment 80 Channel Cycler per Rack
1 . Testing with the uA current unit is more accurate and more convenient .
2 . The lower range is able to output current low as 5uA , which can tell the subtle difference of various materials such electrodes , electrolyte , separator , etc .
3 . Sensitive galvanometer is used for students to check weak current or tiny voltage in DC circuit in the lab . It is a kind of high sensitive magnetoelectric instrument , which can measure the tiny current .
4 . CT-4000 Multi Range mA Battery Testing System , characterized with 0.05 percent of FS accuracy and down to uA capability , enables users to perform DCIR tests , dQ / dV and other basic tests on three - electrode system .
5 . Neware 5V10mA / 20mA / 50mA is born for coin cell test , formerly its 5V1mA this modle . Students and researchers in universities and institutes just love this product , its the real star on their mind .
resolution | AD 16bit , DA 16bit | |
Input Power | 25W | |
Channel Features | Constant Current Source and Constant Voltage Source with Independent pairs of Closed - loop Structure | |
Channel Control Mode | Independent Control | |
Voltage | Per Channel Voltage Range | 0V - 5V |
Discharge Min Voltage | 0V | |
Power | Per Channel Output Power | 0.25W |
Stability | 0.1percent of FS | |
Data Recording | Record Condition | Min Time - 100mS |
Min Voltage - 10mV | ||
Record Frequency | 10Hz | |
Charge | Charge Mode | CCCharge , CVCharge , CCCVCharge , CPCharge |
End Conditon | Voltage , Current , Relative Time , Capacity , -deltaV | |
Discharge | Discharge Mode | CCD , CPD , CRD |
End Condition | Voltage , Current , Relative Time , Capacity | |
Pulse | charge | CCC , CPC |
Discharge | CCD , CPD | |
Min Pulse Width | 500ms | |
Automated Switch | Automated swith from charge to discharge for each pulse | |
End Condition | Voltage, Test Time | |
Protection | Software Protection | Power - down Data Protection |
Off - line Testing Function | ||
Setting Protection Condition,Setting Parameter - Low Voltage limit , Upper Voltage limit , Low Current limit , Upper Current limit , Delay Time | ||
IP protection level | Protection level IP20 | |
Voltage and Current Testing Sample | 4 - wire connecting | |
Per Unit Main Channels No. | 8 | |
Dimensions | 3U , 480 – 404 - 130mm |
![]() |
5uA Electrodes Battery Cell Cycler 80 Channel Cycler Per Rack Images |